Changeset 310445 for doc


Ignore:
Timestamp:
Jun 22, 2017, 10:28:16 PM (8 years ago)
Author:
Frederik Heber <frederik.heber@…>
Branches:
Action_Thermostats, Add_AtomRandomPerturbation, Add_SelectAtomByNameAction, Adding_Graph_to_ChangeBondActions, Adding_MD_integration_tests, Adding_StructOpt_integration_tests, AutomationFragmentation_failures, Candidate_v1.6.1, ChangeBugEmailaddress, ChemicalSpaceEvaluator, EmpiricalPotential_contain_HomologyGraph_documentation, Enhance_userguide, Enhanced_StructuralOptimization, Enhanced_StructuralOptimization_continued, Example_ManyWaysToTranslateAtom, Exclude_Hydrogens_annealWithBondGraph, Fix_Verbose_Codepatterns, ForceAnnealing_oldresults, ForceAnnealing_with_BondGraph, ForceAnnealing_with_BondGraph_continued, ForceAnnealing_with_BondGraph_continued_betteresults, ForceAnnealing_with_BondGraph_contraction-expansion, Gui_displays_atomic_force_velocity, IndependentFragmentGrids_IntegrationTest, JobMarket_RobustOnKillsSegFaults, JobMarket_StableWorkerPool, PythonUI_with_named_parameters, QtGui_reactivate_TimeChanged_changes, Recreated_GuiChecks, StoppableMakroAction, TremoloParser_IncreasedPrecision, TremoloParser_MultipleTimesteps
Children:
8e9217
Parents:
78ea3c
git-author:
Frederik Heber <heber@…> (04/02/17 19:23:15)
git-committer:
Frederik Heber <frederik.heber@…> (06/22/17 22:28:16)
Message:

Added RandomPerturbationAction.

  • this should be when doing structural optimization for getting given configurations out of ambivalent states, e.g. a water molecule whose three atoms define a straight line.
  • note that we need to use a sensible random number distribution, the default is not doing what's expected. Added to docu.
  • TESTS: Added regression test with undo/redo.
  • DOCU: Added documentation to userguide.
File:
1 edited

Legend:

Unmodified
Added
Removed
  • doc/userguide/userguide.xml

    r78ea3c r310445  
    879879        <link linkend='geometry'>Geometry</link>.</para>
    880880        </section>
     881        <section xml:id="atoms.random-perturbation">
     882          <title xml:id="atoms.random-perturbation.title">Randomly perturb atoms</title>
     883          <para>The positions of a set of selected atom(s) can be randomly
     884          perturbed by giving a maximum noise level..</para>
     885          <programlisting>
     886          ... --random-number-distribution "uniform_01"
     887      --random-perturbation 0.1</programlisting>
     888          <para>This will perturb all atomic positions by adding a vector
     889          with components chosen randomly from the interval [-level, level].</para>
     890          <para>Note that the manner these random numbers are picked depends
     891          on the current random number distribution (and also on the engine),
     892          see <link linkend='randomization'>Randomization</link>. The default
     893          one will not give good results, therefore the example uses the
     894          uniform_01 distribution</para>
     895        </section>
    881896        <section xml:id="atoms.remove-atom">
    882897          <title xml:id="atoms.remove-atom.title">Removing atoms</title>